Case Study 2

Remanufacture of 2 off 5m², 316L, Rosenmund Filters.
Fully Remanufacture of equipment:
- New agitator drive units with ATEX gearbox and motor
- Hydraulic base lowering system
- Discharge valve
- All sealing areas
- Upgraded shaft sealing
- Repainting of carbon steel components
- Cleaning and polishing of internal and external surfaces
- ATEX certified hydraulic power packs
- Stand alone PLC control units and MCC panels
- Continuous liner discharge pack off heads
- Warranted remanufacture
- FAT executed and documented at AWL facilities
- SAT executed and documented at the customer’s facility
- Fast and cost effective turnaround
Contact Alconbury Weston to assist with all your future processing equipment requirements or visit our downloads section for this or other case studies.